Cored wire of base metal, for electric arc- welding
Cored wire of base metal for electric arc welding
HSN 8311 20 00 (cored wire of base metal for electric arc welding) is covered by a Bureau of Indian Standards Quality Control Order. Conformity to IS 15769:2008 is mandatory under the ISI Mark Scheme with effect from 1 September 2021 under the Flux Cored (Tubular) Electrodes (Quality Control) Order, 2021. No separate customs-clearance overlay beyond the BIS obligation applies to this tariff line.
- 1Source only from a Bureau of Indian Standards CM/L-licensed manufacturer holding a current licence against IS 15769:2008 for flux cored (tubular) electrodes. Verify the supplier's CM/L number, licensed product scope, and manufacturing facility address on the BIS online register before placing the purchase order.Flux Cored (Tubular) Electrodes (Quality Control) Order, 2021 · S.O. 1203(E) dated 12-03-2021
- 2Ensure every spool or unit of cored wire bears the ISI mark and the supplier's CM/L number per Scheme-I of Schedule-II of the Bureau of Indian Standards (Conformity Assessment) Regulations, 2018. Marking must appear on the product or its primary packaging as required under the licensed marking format.Scheme-I of Schedule-II of the BIS (Conformity Assessment) Regulations, 2018 · Flux Cored (Tubular) Electrodes (Quality Control) Order, 2021
- 3Confirm in writing that the supplier's CM/L scope covers the specific electrode classification — gas-shielded or self-shielded, carbon steel or carbon-manganese steel — matching the consignment. A CM/L covering a different electrode class or wire diameter range does not extend to the consignment.IS 15769:2008 · Flux Cored (Tubular) Electrodes (Quality Control) Order, 2021 · S.O. 1203(E) dated 12-03-2021
- 4Quote the supplier's BIS CM/L number on the bill of entry. Customs verifies the CM/L in real time against the BIS register; an absent, expired, or scope-mismatched licence triggers consignment detention, demurrage, and potential re-export or confiscation.BIS Act, 2016 · Customs Act, 1962 · Flux Cored (Tubular) Electrodes (Quality Control) Order, 2021
- 5If the supplier claims a micro-enterprise exemption, verify Udyam Portal registration and obtain a Chartered Accountant certificate confirming investment in plant and machinery does not exceed ₹1 crore and turnover does not exceed ₹5 crore for the previous financial year. The exemption under the Welding Rods and Electrodes (Quality Control) Order, 2023 does not apply to the IS 15769:2008 QCO.Welding Rods and Electrodes (Quality Control) Order, 2023 · S.O. 3153(E) dated 14-07-2023 · MSMED Act, 2006 (27 of 2006)
The single most common error on this tariff line is conflating the IS 15769:2008 obligation (flux cored tubular electrodes for arc welding) with the separately notified IS 814:2004 and IS 6419:1996 regime (covered and bare electrodes under the Welding Rods and Electrodes QCO). Importers sourcing from a supplier whose CM/L is issued under IS 814 or IS 6419 — and not IS 15769 — will face detention at port because the licence does not extend to cored wire under HSN 8311 20 00, regardless of the supplier's general welding-consumables credentials.