Skip to main content
Access IndiaPLATFORM
HomeHSNChapter 73HSN 7321 12 20

Other stoves

Liquid-fuel oil pressure stoves of iron or steel

BIS QCO APPLICABLE · ISI MARK SCHEME · IS 2787 · SIMS OVERLAY

HSN 7321 12 20 (other stoves for liquid fuel) is covered by multiple Bureau of Indian Standards Quality Control Orders. Conformity to IS 2787, IS 10109, and IS 1342 is mandatory under the ISI Mark Scheme by virtue of the Oil Pressure Stoves (Quality Control) Order, 1997, with IS 17153:2019 applicable to domestic gas stoves for piped natural gas with effect from 12 February 2024. Steel Import Monitoring System (SIMS) registration administered by the Directorate General of Foreign Trade applies as a separate customs-clearance overlay.

What this is
HSN code
7321 12 20
Chapter
73 · Articles of iron or steel
BIS QCO
Applicable · ISI Mark Scheme · CM/L required
Indian Standard
IS 2787 · effective 12-02-2024
Applicable Partner Government Agencies
BISBIS·Bureau of Indian Standards
SIMSSIMS·Steel Import Monitoring System

Procedural directions for customs clearance are issued by: Directorate General of Foreign Trade.

Compliance steps
  1. 1
    Determine which Indian Standard governs the specific product being imported: IS 10109 for oil pressure stoves of the offset-burner type, IS 2787 for multi-burner oil pressure stoves, IS 1342 for oil pressure stoves generally, and IS 17153:2019 for domestic gas stoves for piped natural gas. Source only from a BIS CM/L-licensed manufacturer holding a current licence against the applicable standard.
    Oil Pressure Stoves (Quality Control) Order, 1997 · S.O. 451(E) dated 16-06-1997; Domestic Gas Stoves for Use with Piped Natural Gas (Quality Control) Order, 2023 · S.O. 3584(E) dated 09-08-2023
  2. 2
    Verify the supplier's CM/L licence number, licensed product scope (stove type, burner configuration), and manufacturing facility address on the BIS online register. Confirm the licence covers the specific product variant and manufacturing plant before placing the purchase order.
    ISI Mark Scheme under Scheme-I of Schedule-II to the BIS (Conformity Assessment) Regulations, 2018
  3. 3
    Ensure every stove in the consignment bears the ISI mark and the supplier's CM/L number, traceable to the licensed manufacturing facility. Marking must appear on the product itself, not on the packaging alone.
    Scheme-I of Schedule-II to the BIS (Conformity Assessment) Regulations, 2018 · S.O. 451(E) dated 16-06-1997
  4. 4
    Register the consignment on the Steel Import Monitoring System portal not earlier than 60 days before the expected arrival date. Fee ₹500; the automatic registration number is valid for 75 days. The prior requirement of 15-day advance registration has been abolished.
    DGFT Notification 33/2015-20 dated 28-09-2020 · DGFT Notification 28/2023 dated 28-08-2023 · DGFT Notification 19/2015-20 dated 07-07-2022
  5. 5
    Quote both the supplier's BIS CM/L number and the SIMS registration number on the bill of entry. Customs verifies the CM/L in real time against the BIS register and the SIMS registration against the DGFT portal; either being absent, expired, or scope-mismatched triggers consignment detention.
    ITC HS policy condition 2 of Chapter 73 · BIS Act, 2016 · Customs Act, 1962
A word of counsel

The single most common error on this tariff line is treating the three oil-pressure-stove standards as interchangeable and obtaining a CM/L against the wrong IS number for the actual product variant. IS 10109, IS 2787, and IS 1342 each cover a distinct stove configuration; a CM/L licensed against IS 2787 for multi-burner stoves does not cover offset-burner type stoves governed by IS 10109. Customs detention follows when the product type on the shipping documents does not match the licensed standard scope on the BIS register.

Need a regulatory steer on this product?
Speak to a regulatory counsel about your specific HSN, IS, and supplier situation.
Speak to an Expert
Frequently asked
Does HSN 7321 12 20 require BIS certification?
Yes. Liquid-fuel oil pressure stoves under this tariff line are subject to the ISI Mark Scheme. IS 10109 covers offset-burner type stoves, IS 2787 covers multi-burner oil pressure stoves, and IS 1342 covers oil pressure stoves generally; a current CM/L licence against the applicable standard is mandatory.
Is SIMS registration required separately from BIS QCO compliance?
Yes. Steel Import Monitoring System registration is administered by the Directorate General of Foreign Trade and is independent of the BIS QCO obligation. Fee ₹500, validity 75 days; apply no earlier than 60 days before the expected arrival date.
Does IS 17153:2019 apply to all stoves under this HSN, and are there phased dates for small and micro enterprises?
IS 17153:2019 applies specifically to domestic gas stoves for piped natural gas under the Domestic Gas Stoves (Quality Control) Order, 2023; the effective date is 12-02-2024 for general importers, 12-05-2024 for small enterprises, and 12-08-2024 for micro enterprises as defined under the MSMED Act, 2006.
Does a single CM/L licence cover all oil pressure stove variants from the same manufacturer?
No. Each CM/L is standard-specific and product-scope-specific; a licence against IS 2787 for multi-burner stoves does not authorise import of offset-burner or single-burner variants governed by IS 10109 or IS 1342.
Last verified against gazette notifications: 2026-05-18. Source: BIS / SIMS / DGFT / Indian Customs CUSDATA.