Skip to main content
Access IndiaPLATFORM
HomeHSNChapter 73HSN 7321 11 90

Other

Gas and oil-fuel domestic cooking appliances (gas stoves, oil pressure stoves, PNG stoves)

BIS QCO APPLICABLE · ISI MARK SCHEME · IS 10109 · BEE OVERLAY · SIMS OVERLAY

HSN 7321 11 90 (gas and oil-fuel domestic cooking appliances) is covered by multiple Bureau of Indian Standards Quality Control Orders. Conformity to IS 4246, IS 10109, IS 2787, IS 1342, or IS 17153:2019 is mandatory under the ISI Mark Scheme, with the most recent enforcement date of 12 February 2024 applying to domestic gas stoves for piped natural gas. Steel Import Monitoring System registration administered by the Directorate General of Foreign Trade and Bureau of Energy Efficiency labelling apply as separate customs-clearance overlays.

What this is
HSN code
7321 11 90
Chapter
73 · Articles of iron or steel
BIS QCO
Applicable · ISI Mark Scheme · CM/L required
Indian Standard
IS 10109 · effective 12-02-2024
Applicable Partner Government Agencies
BEEBEE·Bureau of Energy Efficiency
BISBIS·Bureau of Indian Standards
SIMSSIMS·Steel Import Monitoring System

Procedural directions for customs clearance are issued by: Directorate General of Foreign Trade.

Compliance steps
  1. 1
    Identify the precise product type before sourcing: domestic LPG gas stoves (IS 4246), oil pressure stoves offset-burner type (IS 10109), multi-burner oil pressure stoves (IS 2787), oil pressure stoves general (IS 1342), or piped natural gas stoves (IS 17153:2019). The applicable IS standard and QCO notification differ by fuel type and burner configuration.
    Domestic Gas Stoves for Use with Liquefied Petroleum Gases (Quality Control) Order, 2019 · S.O. 4345(E) dated 03-12-2019; Oil Pressure Stoves (Quality Control) Order, 1997 · S.O. 451(E) dated 16-06-1997; Domestic Gas Stoves for Use with Piped Natural Gas (Quality Control) Order, 2023 · S.O. 3584(E) dated 09-08-2023
  2. 2
    Source only from a Bureau of Indian Standards CM/L-licensed manufacturer holding a current licence against the applicable IS standard. Verify the supplier's CM/L number, licensed product scope, fuel type, burner configuration, and licensed manufacturing facility address on the BIS online register before placing the purchase order.
    Scheme-I of Schedule-II of the BIS (Conformity Assessment) Regulations, 2018 · S.O. 3584(E) dated 09-08-2023
  3. 3
    Ensure every appliance bears the ISI mark and the supplier's CM/L number on the product itself, not only on packaging. For PNG stoves under IS 17153:2019, confirm that the licensed scope explicitly covers piped natural gas fuel type; a CM/L for LPG stoves does not satisfy the PNG QCO requirement.
    Domestic Gas Stoves for Use with Piped Natural Gas (Quality Control) Order, 2023 · S.O. 3584(E) dated 09-08-2023; BIS (Conformity Assessment) Regulations, 2018
  4. 4
    Register the consignment on the Steel Import Monitoring System portal not earlier than 60 days before the expected date of arrival. Fee ₹500; registration valid for 75 days from issue. The minimum 15-day advance registration requirement has been abolished.
    DGFT Notification 33/2015-20 dated 28-09-2020; DGFT Notification 19/2015-20 dated 07-07-2022; DGFT Notification 28/2023 dated 28-08-2023
  5. 5
    Quote the supplier's BIS CM/L number and the SIMS registration number on the bill of entry. Ensure compliance with the Bureau of Energy Efficiency (Appliance Labelling and Compliance) Regulations, 2026. Customs verifies the CM/L in real time against the BIS register; an absent, expired, or scope-mismatched licence triggers consignment detention.
    ITC HS policy condition 2 of Chapter 73; BEE Notification 5506/BEE/S&L/AL/2025-26 dated 26-12-2025; BIS Act, 2016; Customs Act, 1962
A word of counsel

The single most common error on this tariff line is procuring a CM/L licence valid for one fuel-type variant and presenting it at customs for a different variant — most critically, using an LPG-stove CM/L (IS 4246) to clear a piped natural gas stove consignment (IS 17153:2019) or an oil pressure stove (IS 10109/IS 2787/IS 1342). Each QCO and each IS standard is fuel-type- and burner-configuration-specific; a licence that does not expressly cover the imported product's fuel type and configuration is treated as absent, resulting in detention regardless of the supplier's otherwise valid BIS registration.

Need a regulatory steer on this product?
Speak to a regulatory counsel about your specific HSN, IS, and supplier situation.
Speak to an Expert
Frequently asked
Does HSN 7321 11 90 require BIS certification?
Yes. Depending on fuel type and burner configuration, certification is mandatory under IS 4246, IS 10109, IS 2787, IS 1342, or IS 17153:2019 under the ISI Mark Scheme; import is permitted only from manufacturers holding a current BIS CM/L licence covering the specific product variant.
Is SIMS registration required separately from BIS QCO compliance?
Yes. Steel Import Monitoring System registration is administered by the Directorate General of Foreign Trade and is independent of the BIS QCO obligation. Fee ₹500, validity 75 days; apply no earlier than 60 days before the expected arrival date.
Do the MSME-phased enforcement dates for PNG stoves affect all importers?
No. The general enforcement date for piped natural gas stoves under S.O. 3584(E) is 12-02-2024; the deferred date for small enterprises is 12-05-2024 and for micro enterprises as defined under the Micro, Small and Medium Enterprises Development Act, 2006 is 12-08-2024.
Does a single CM/L licence cover all gas and oil stove variants from the same manufacturer?
No. A CM/L licence is product-specific by IS standard, fuel type, burner type, and licensed manufacturing facility; stove variants outside the licensed scope, or manufactured at an unlicensed plant, are not covered and customs will detain the consignment on a scope mismatch.
Last verified against gazette notifications: 2026-05-18. Source: BIS / BEE / SIMS / DGFT / Indian Customs CUSDATA.
Related